Sign In | Join Free | My himfr.com
Home > Yokogawa Instruments >

85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers
     
    Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers
    • Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers
    • Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers
    • Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers
    • Buy cheap 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer from wholesalers

    85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer

    Ask Lasest Price
    Brand Name : Yokogawa
    Model Number : ZR402G-M-E-E-A/SCT
    Certification : ATEX
    Price : Negotiate
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : stock
    • Product Details
    • Company Profile

    85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer

    Yokogawa ZR402G-M-E-E-A/SCT Separate type Zirconia Oxygen Analyzer, Converter


    Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

    The ZR402G converter is equipped with an LCD touch screen which has various setting displays, a calibration display, oxygen concentration trend display, with easier operation and improvement of display functions. The converter is equipped with various standard functions such as measurement and calculation as well as maintenance functions including self-test. The ZR22G separate-type detector uses a high-reliability zirconia sensor, and its heater assembly can be replaced on site. The detector is mounted, for example, on the wall of a flue and can measure the gases directly. The ZR22S separate-type detector for explosion-proof applications is also available.


    Specifications


    • Measurement object Oxygen concentration in combustion exhaust gas and mixed gas

    • Measurement system Zirconium oxide sensor

    • Measurement range 0.01 to 100 vol% O2

    • Output signal 4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)

    • Setting range Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range

    • Digital communication (HART) 250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)

    • Sample gas pressure -5 to +250 kPa (Pressure compensation option necessary over +5 kPa)

    • Sample gas temperature 0 to 700℃ (Probe only)

    • 700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)

    • Probe length 0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m

    • Contact output Four points (one is fail-safe, normally open)

    • Contact input Two points

    • Calibration Method; zero/span calibration

    • Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)

    • Construction of detector (ZR22G) Heater and thermocouple replaceable construction.

    • Non-explosion-proof. Equivalent to NEMA4X/IP66

    • Construction of converter (ZR402G) Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66

    • Ambient Temperature

      Probe (ZR22G): -20 to 150℃

      Converter (ZR402G): -20 to 55℃)

    • Reference Gas System

      Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

      Natural convection

    • Power supply 85 to 264 V AC; 45 to 66 Hz


    1736821042877.png


    AAT145-S00EB501-50SC42-SP34
    ACCC01F9342LP-05SC4AJ-S-AD-09-002-05-T1
    ACM12F9802JBSCP451-51
    ACM12FLXA21-D-P-D-AB-C1-NN-A-N-LA-N-NN-USDV144-S63
    ADM11cFLXA402-A-B-AB-C1-NN-A2-NR-N-R-N-NNSDV541
    ADM12FLXA402-A-B-AB-C5-NN-A2-NR-N-R-N-NNSDV541-S33
    ADM52CFU20-10-T1-NPTSR20-AC22
    ADV151-P00FU20-VP-T1-FTS/NTISR20-AP26
    ADV151-P50/D5A00GCRV-GBCRSCNN3700UM33A-000-10-LP
    ADV151-P63HHR-21AHF2A1UM33A-000-11
    ADV151-P63/D5A00ISC40G-TG-T1-10UM33A-000-11-LP
    ADV159-P00K9034DNUP55A-000-10-00
    ADV551K9142THUP55A-000-11-00
    ADV551-P50/D5A00K9142TKUT130-RN-AL
    ADV551-P63K9142TNUT32A-000-11-00
    AED5D-00K9192QAUT55A-000-10-00
    AIP601K9192TGUT55A-001-10-00
    AIP826K9194TAUT55A-040-11-00
    AIP827-2K9194XAVF701
    AIP830-101K9402VGVJA1-016-AANO
    AIP830-101-EIM-VESAK9409AWVJA1-027-AA60
    AKB331-M020K9802MAVJH1-026-AAA0
    ALE111-S50K9804JAWU10-V-S-05
    ALE111-S51L9819ACYCB138
    ALR121-S00M1234SE-AYS110-001

    Quality 85V - 264V ZR402G-M-E-EA SCT Yokogawa Instruments Separate Zirconia Oxygen Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Achievers Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)