Sign In | Join Free | My himfr.com
Home > Pepperl Fuchs Safety Barrier >

Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD)

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers
     
    Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers
    • Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers
    • Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers
    • Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers
    • Buy cheap Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) from wholesalers

    Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD)

    Ask Lasest Price
    Brand Name : PEPPERL FUCHS
    Model Number : KFU8-UFC-1.D
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD)

    Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D

    1-channel signal conditioner

    Universal usage at different power supplies

    Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts

    Input frequency 1 mHz ... 10 kHz

    Current output 0/4 mA ... 20 mA

    Relay contact and transistor output

    Start-up override

    Line fault detection (LFD)

    Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

    General specifications

    Signal type Digital Input

    Functional safety related parameters

    Safety Integrity Level (SIL) SIL 2

    Supply

    Connection terminals 23, 24

    Rated voltage 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz

    Power dissipation/power consumption ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA

    Interface

    Programming interface programming socket

    Input

    Connection side field side

    Connection Input I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3

    input II: terminals 13+, 14- start-up override;

    Input I 2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact

    Open circuit voltage/short-circuit current 22 V / 40 mA

    Input resistance 4.7 kΩ

    Switching point/switching hysteresis logic 1: > 2.5 mA ; logic 0: < 1.9 mA

    Pulse duration > 50 µs

    Input frequency 0.001 ... 10000 Hz

    Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 4 mA

    Input II startup override: 1 ... 1000 s, adjustable in steps of 1 s

    Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA

    Open circuit voltage/short-circuit current 18 V / 5 mA

    Output

    Connection side control side

    Connection output I: terminals 10, 11, 12

    output II: terminals 16, 17, 18

    outout III: terminasl 19+, 20-

    output IV: terminals 8+, 7-

    Output I, II signal, relay

    Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A

    Mechanical life 5 x 107 switching cycles

    Energized/De-energized delay approx. 20 ms / approx. 20 ms

    Output III electronic output, passive

    Contact loading 40 V DC

    Signal level 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)

    0-signal: blocked output (off-state current ≤ 10 µA)

    Output IV analog

    Current range 0 ... 20 mA or 4 ... 20 mA

    Open loop voltage max. 24 V DC

    Load max. 650 Ω

    Fault signal downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)

    Transfer characteristics

    Input I

    Measuring range 0.001 ... 10000 Hz

    Resolution 0.1 % of the measurement value , ≥ 0.001 Hz

    Accuracy 0.1 % of the measurement value , > 0.001 Hz

    Measuring time < 100 ms

    Influence of ambient temperature 0.003 %/K (30 ppm)

    Output I, II

    Response delay ≤ 200 ms

    Output IV

    Resolution < 10 µA

    Accuracy < 20 µA

    Influence of ambient temperature 0.005 %/K (50 ppm)

    Galvanic isolation

    Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Output III/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Output III/IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

    Output IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Start-up override/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Interface/output III basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

    Indicators/settings

    Display elements LEDs , display

    Control elements Control panel

    Configuration via operating buttons

    via PACTware

    Labeling space for labeling at the front

    Directive conformity

    Electromagnetic compatibility

    Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

    Low voltage

    Directive 2014/35/EU EN 61010-1:2010

    Conformity

    Electromagnetic compatibility NE 21:2006

    Degree of protection IEC 60529:2001

    Ambient conditions

    Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

    Mechanical specifications

    Degree of protection IP20

    Connection screw terminals

    Mass 300 g

    Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2

    Height 119 mm

    Width 40 mm

    Depth 115 mm

    Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

    Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD)




    Quality Pepperl Fuchs Frequency Converter with Trip Values KFU8-UFC-1.D Line fault detection (LFD) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Achievers Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)