Sign In | Join Free | My himfr.com
Home > Pepperl Fuchs Safety Barrier >

Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers
     
    Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs from wholesalers

    Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs

    Ask Lasest Price
    Brand Name : PEPPERL FUCHS
    Model Number : RD0-FB-Ex4.*
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs

    Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.*
    4 outputs Ex ia IIC
    FieldBarrier in Zone 1/Div. 2
    Instruments in Zone 0...1/Div. 1
    Short circuit current limitation per output
    For FOUNDATION Fieldbus H1 and PROFIBUS PA
    Power, Com, and Error LEDs
    Supports FISCO and Entity
    Integrated cable tie-downs
    Supports all grounding methods
    General specifications
    Fieldbus barrier, module for DIN rail mounting
    General specifications
    Design / Mounting Cabinet installation
    Installation in hazardous area Zone 1 / Div. 2
    Fieldbus connection
    Main cable (Trunk)
    Connection input (Trunk IN): terminals 3+, 4-, 5s
    output (Trunk OUT): terminals 7-, 8+, 6s
    Rated voltage 32 ... 16 V DC
    Rated current 31 mA ... 26 mA (without load)
    77 mA ... 115 mA (at 20 mA load per input)
    120 mA ... 209 mA (at 40 mA load per input)
    135 mA ... 241 mA (short-circuit on all outputs)
    Voltage drop trunk IN to trunk OUT 100 mV max.
    Number of couplers max. 4 per segment
    Outputs
    Number of devices per output 1
    Connection output 1: terminals 10+, 11-, 12S shield;
    output 2: terminals 13+, 14-, 15S shield;
    output 3: terminals 16+, 17-, 18S shield;
    output 4: terminals 19+, 20-, 21S shield
    Rated voltage 10 ... 13 V
    Rated current max. 43 mA
    Short-circuit current 50 mA
    Indicators/operating means
    LED voltage Fieldbus green: on, bus voltage existent
    LED status output red flashing: short-circuit
    Galvanic isolation
    Main wire/outputs isolation is not affected by interference according to EN 50020, voltage peak value 375 V
    Directive conformity
    Electromagnetic compatibility
    Directive 2014/30/EU EN 61326-1:2013
    Standard conformity
    Electromagnetic compatibility NE 21:2006
    Degree of protection IEC/EN 60529
    Fieldbus standard IEC 61158-2
    Climatic conditions DIN IEC 721
    Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
    Ambient conditions
    Ambient temperature -50 ... 70 °C (-58 ... 158 °F)
    Storage temperature -40 ... 85 °C (-40 ... 185 °F)
    Mechanical specifications
    Connection type screw terminal
    Core cross section up to 2.5 mm2
    Housing see figure 1
    Housing material Polycarbonate
    R... DIN rail housing PA 6.6
    Degree of protection IP20
    Mass 1050 g
    Mounting DIN rail mounting
    Data for application in connection with hazardous areas
    EU-type examination certificate PTB 02 ATEX 2086
    Marking Ex-Hexagon II 2 (1) G Ex eb mb [ia Ga] IIC T4 Gb ,
    Ex-Hexagon II (1) D [Ex ia Da] IIIC
    Main cable (Trunk)
    Maximum safe voltage Um 253 V AC
    Outputs
    Power 975 mW
    Voltage 15.75 V
    Current 248 mA
    Directive conformity
    Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+A1:2017
    International approvals
    FM approval CoC 3015728
    Control drawing 116-0266
    Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx nA [ia] IIC T4
    CSA approval CoC 1845315
    Control drawing 116-0266
    Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, Ex nA [ia] IIC T4
    IECEx approval IECEx PTB 03.0003
    Approved for Ex eb mb [ia Ga] IIC T4 Gb , [Ex ia Da] IIIC
    Certificates and approvals
    FOUNDATION Fieldbus FF-846
    Marine approval DNV A-14038